Location -
The switch/light is located on the pilot's switch panel in
the cockpit.
View of
pilot's switch panel
1.
L GEN Switch (SI025)
2. R
GEN Switch (SI026)
3.
Left Ammeter
(A1)
4.
Right Ammeter (A2)
Operation -
The R GEN switch activates the Right
Start/Generator (SG2) through the Right Generator Control Unit
(BT002). The switch has three positions: ON, OFF, and RESET.