The set of
four LED fault indicators located on the face of the Left
and Right Generator Control Unit (BT001
and BT002) illuminate to
display a fault pattern. Refer to the following
table for a description of each fault pattern:
NOTE:
Fault patterns are read from left to right with technician
looking at the face (display area) of the GCU.
|
Fault Code Legend |
Description |

|
LED Illuminated |

|
LED Extinguished |
NOTE:
The following indications are visible only with the L GEN
or R GEN Switch (SI025 or SI026)
held in the RESET position.
|
LED Fault
Pattern
|
Fault Displayed
|
Function
|
 |
NO FAULTS
|
No
faults; system functioning properly.
|
|
BUILD UP GF
|
Build
up ground fault - generator current >200A while power relay (KLC)
was off.
|
|
OPEN POR
|
POR
(pin B) sensing wire open
|
|
QIKTRIP OV
|
Quick
Overvoltage trip (GCU failure)
|
|
GROUND FAULT
|
Ground
Fault according to CT signal - pin M to m.
|
|
OVEREXCITE
|
Overexcitation
- check pins W and p.
|
|
OVERVOLT
|
Overvoltage
detected.
|
|
OPEN SHUNT
|
Open
shunt engine start - check connections to generator - pins (AA,
DD, y, B).
|
|
SHORT SHUNT
|
Field
current exceeded 20A on pin AA.
|
|
KFR BIT FAIL
|
Failed
KFR (GCU failure) field relay inside GCU.
|
|
GF BIT FAIL
|
Failed
GF test (GCU failure)
|
|
REGULATOR
|
Regulator
failed to energize during engine start (GCU failure).
|
|
KLC SHORT
|
Line
contactor driver (pin L or J) overloaded or failed to turn ON.
|
|
KSR SHORT
|
Start
contactor driver (pin L or J) overloaded or failed to turn ON.
|
|
MPU Open
|
No
speed pickup (pin X to Y) signal.
|